Matrix: How can I control the 4x GPI inputs on the V series panels?

Matrix: How can I control the 4x GPI inputs on the V series panels?

The V series panels seem to have 4 GPI inputs and the manual seems to say that they are all assignable although 3 & 4 have default functions. In the matrix hardware section I can select a function for GPIs 1 and 2 but can’t change 3 & 4. How do I control these two?
The V series panels are fitted as standard with 4x GPI inputs and 2x Relay outputs. These are accessed on rear of the panel and programmed by the ECS configuration software.
V-Panel GPI #1, 2 are freely assignable to other functionsV-Panel GPI #3 and 4 have fixed assignments (see below)

GPI#3 – is used for the Reply key (hence activating it, is the same as pressing the reply key on your panel)GPI#4 – is used to exit Supervisor mode.








CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.