Matrix: Is it possible to enable the call signal from a V-Series Panel through a CCI-22 to a tempest beltpack?

Matrix: Is it possible to enable the call signal from a V-Series Panel through a CCI-22 to a tempest beltpack?

The simple answer is yes: On the Vpanel press and hold the two small blue scrollup/down buttons associated with the key for the CCI-22 port After about 1 secthe display should change to say "call signal"  This will send a call signal out of the CCI-22 port andinto the Tempest base  Or if you want the CCI-22 to send a call signal any timea Vpanel user talks to the Tempest then in ECS go to card/ports select theCCI-22 port and in the advance settings set the tick box auto-signal to true BTW: remember that you need a PSU like a PK-7 or PS-702between the CCI-22 and the Tempest unit 

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.