LQ: I get a solid call signal when connecting an LQ4W2 to a FSII-Base via 4-wire

LQ: I get a solid call signal when connecting an LQ4W2 to a FSII-Base via 4-wire

When I connect LQ to FreeSpeak basestation (FSI or FSII-Base) via a straight CAT5 cable, I get a call signal across any devices connected in an LQ channel.
Solution: There are data pins on the FSII-Base 4-wire 1 and 2 ports. These are unused and will be seen at the LQ data input as a constant call signal.
Do not connect these pins  (RJ45 pins 1,2 & 7,8) when using LQ and Freespeak (FSI or FSII-Base). 4-wire ports 3 and 4 do not have these pins connected so this does not apply.
FSII-BaseII has data pins for passing call signal so straight cables can be used without issue.






Keywords: Freespeak I, LQ-R 

Related content

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.