Question:  How can I tell if 2-wire / 4-wire modules are properly connected to my v3.0 HelixNet HMS-4X main station?
Answer:  Two places on HMS-4X to verify how good or bad the module detection goes:
1. In Diagnostics->Hardware->Slot N PCB you should see things like internal part number and serial number of the module.
If you see None in the slot where something should be, it means that the problem is electrical or mechanical. Like the module
is not properly inserted, is broken, or the connector is broken either on the module or on the HMS. Try a different slot or a
different HMS to make sure.
2. If the module shows up in Diagnostics->Hardware->Slot N PCB but not in the Modules->2W/4W Slot N Port Y, it means that
the processor on the module is either not powering up properly or cannot connect properly to the HMS main processor.
Version mismatch and configuration corruption are the most common problems. You might be able to see the software version in Administration->Software->Current->2W/4W Slot N Port Y. Reset to default might help. Downgrading/Upgrading again might help
as well.
Downloading the logs to USB stick from the advanced menus and sending them in to Clear-Com may be necessary to track down
a module not booting up properly / base station main board issue. 

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.