Wireless: Are the DX410 base station 2W ports terminated / unterminated?

Wireless: Are the DX410 base station 2W ports terminated / unterminated?

As shipped from the factory DX410 base stations 2-wire ports are internally jumpered with the 200 ohm termination set to the "OFF" position.  This requires that a 2-wire powered PL system (Clear-Com and RTS) be attached to the DX410 base station in order to use the 2-wire functionality of the base station. 
If the base station is to be used in standalone mode with multiple bases connected together using the 2-wire ports to tie the audios together one base station will need the 2-wire ports terminated so that the 2-wire ports can be connected together.  See pcb picture below for jumper locations and see chart describing what the jumpers functionality are. 




















Related content

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.