Partyline: What is the purpose of the jumpers JB1 and JB2 on the MR-202 PL panel?
Partyline: What is the purpose of the jumpers JB1 and JB2 on the MR-202 PL panel?
Question: We have several MR-202 headset remote stations. One of these has lost its latching ability, and we are assuming it will need to be replaced. The MR-202 works fine otherwise. Is it possible to have the latching function repaired?
Answer:
JB2—Latch Disable
Check that the internal jumper on JB2 is not in the closed position. Setting the Latch Disable jumper to the CLOSED (both pins connected) position will disable the latching function of the Talk button. In this mode, the Talk button must be held in continuously while the operator is talking.
JB1—Long Line
If a long cable run is unavoidable and approaches 1,000 ft. or more, set the Long Line option jumper to the CLOSED (both pins connected) position. The ability to set a sidetone null depends upon properly setting this jumper.
Note: The default position of the jumpers is in the OPEN (only one pin connected) position.

Note the MR-202 is discontinued and has been replaced by the HB-702 unit http://www.clearcom.com/product/partyline/wall-mount%2Cspeaker-stations
Answer:
JB2—Latch Disable
Check that the internal jumper on JB2 is not in the closed position. Setting the Latch Disable jumper to the CLOSED (both pins connected) position will disable the latching function of the Talk button. In this mode, the Talk button must be held in continuously while the operator is talking.
JB1—Long Line
If a long cable run is unavoidable and approaches 1,000 ft. or more, set the Long Line option jumper to the CLOSED (both pins connected) position. The ability to set a sidetone null depends upon properly setting this jumper.
Note: The default position of the jumpers is in the OPEN (only one pin connected) position.
Note the MR-202 is discontinued and has been replaced by the HB-702 unit http://www.clearcom.com/product/partyline/wall-mount%2Cspeaker-stations
, multiple selections available,
Related content
Partyline: MS-704, RM-704, SB-704 Internal IFB J10 Jumper settings
Partyline: MS-704, RM-704, SB-704 Internal IFB J10 Jumper settings
More like this
Partyline: Describe the AB-120 internal dipswitches and jumpers
Partyline: Describe the AB-120 internal dipswitches and jumpers
More like this
Partyline: How do I wire up two channels of PL intercom to an MR-202 wall mount panel?
Partyline: How do I wire up two channels of PL intercom to an MR-202 wall mount panel?
More like this
Partyline: What are the functions of the internal KB-702 controls / dip swtiches?
Partyline: What are the functions of the internal KB-702 controls / dip swtiches?
More like this
Partyline: Footswitch usage
Partyline: Footswitch usage
More like this
Partyline: Can the KB-702 talk switch be permanently enabled to the "On" position?
Partyline: Can the KB-702 talk switch be permanently enabled to the "On" position?
More like this
CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT
This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..
The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.