Matrix: Networked Eclipse matrices reporting no-trunk and system down messages
Networked Eclipse matrices reporting no-trunk and system down messages
System running ECS V5.0System experiencing no-tk (no trunk) and sysdn (system down) messages even when no trunks are in use. normally these message maybe seem if all trunk lines between the matrices are in use and there is no spare trunk line available or the remote matrix is down (sysdn) because of a system reset.
However the customer was seeing these message no-tk (no trunk) and sysdn (system down) messages even when no trunks are in use or there was light traffic between the matrices.
Determined to be caused by Ethernet buffers on some Matrices getting full and not recovering.
Complete linked-network was upgraded to v5.1. Many improvements have been made to the Ethernet stack, and the number of IP messages sent has been reduced due to the reintroduction of some broadcast messages.