Partyline: Can the MS-702 PL panel power one channel while the other is shorted?

Question:  Can I continue to use the MS-702 party-line mains panel if one channel reads a shorted line?  Is the second PL channel still capable of working properly?
Answer:  The MS-702 provides DC power to operate Clear-Com beltpacks and remote stations. The power is distributed between the two channels and will support up to 40 RS-601 beltpacks or 10 speaker stations or 12 headset stations.
Clear-Com’s PSU (power supply unit) design automatically shuts down the power to a channel when a short circuit or electronic overload is sensed on that channel. The other channel will continue to operate normally. Once the fault condition is removed, the MS-702’s power supplys circuit will restore power, even under full load conditions.  LED indicators signal a short or overload on either channel.
The DC power output details are:
• 1.2A continuous output
• 2A peak output (not exceeding the 1.2A rating for more than 2 seconds per 1 minute period)
The MS-702 will operate from any AC line voltage between 100 and 240 volts AC at 50 or 60 Hz.

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.