Matrix: ECS / EHX Global IFB hardware and software setup with IFB-104

Matrix: ECS / EHX Global IFB hardware and software setup with IFB-104

The diagrams below show the user how to initially setup hardware and software for Global IFBs in a small studio application.
Note:  Solution is attached below as a PDF.

  • Hardware Setup

























  • Software Setup
1.  Open ECS / EHX and go the “Cards and Ports” screen, highlight the port that is to be declared as a Global IFB and then open the “Advanced Setting” column option for “Global Options”, enable Global IFB and enable specific Dimming Level

















2.  Open the Local Advanced screen forced listens tab and set a forced crosspoint from the IFB source to the IFB destination by right-clicking on the intersection of the crosspoint on the grid


























3.  Open the Panel Programming screen and place the Global IFB destination keys on the panel as Red talk keys, Green listen keys will monitor IFB source audio















4.  Complete the Global IFB setup by applying the change in ECS / EHX

  File Modified

PDF File Eclipse Global IFB IFB-104 wiring and programming.pdf Eclipse Global IFB IFB-104 wiring and programming.pdf

Apr 06, 2019 by Administrator

Related content

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.