Matrix: No audio on fibre linked frames when one frame is powered off

Matrix: No audio on fibre linked frames when one frame is powered off

We have a system configured as 










































-If a Fiber is disconnected in Ring A or Ring B, in S1, or S2, or S3, or S4 > All is OK : 4WireTest is Available for listen in all matrices
But :
-If S1 is power OFF > 4WireTest is NO AUDIO in S3 and S4-If S3 is power OFF > 4WireTest is NO AUDIO in S1 and S4-If S1 FiberCard is removed > 4WireTest is NO AUDIO in S3 and S4-If S3 FiberCard is removed > 4WireTest is NO AUDIO in S1 and S4

It would appear that the fibre rings are crossing over in two or more places. Have the customer disconnect the B ringeverywhere and test if they have proper two-way comms between to systems. (ensure you can talk and listen between between all matrices). Its unlikely that with the faults you have described that you will get two-way comms between all matrices
Then work on getting ring A to work properly. Only when it does, you can start connecting ring B back. That way you can make sure there is nocrossover. Finally get the fibre RX /TX labelled accordingly.
The customer shouldalso make sure they connect ring A in direction 1 > 2 > 3 > 4 > 1 and ring Bin direction of 1 > 4 > 3 > 2 > 1. Otherwise the fibre loopback will notwork.

Customer reply: Fixed,You are right !
Both ring was 1>2>3>4
it's Ok now.























CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.