Matrix: No audio on fibre linked frames when one frame is powered off
We have a system configured as
-If a Fiber is disconnected in Ring A or Ring B, in S1, or S2, or S3, or S4 > All is OK : 4WireTest is Available for listen in all matrices
But :
-If S1 is power OFF > 4WireTest is NO AUDIO in S3 and S4-If S3 is power OFF > 4WireTest is NO AUDIO in S1 and S4-If S1 FiberCard is removed > 4WireTest is NO AUDIO in S3 and S4-If S3 FiberCard is removed > 4WireTest is NO AUDIO in S1 and S4
It would appear that the fibre rings are crossing over in two or more places. Have the customer disconnect the B ringeverywhere and test if they have proper two-way comms between to systems. (ensure you can talk and listen between between all matrices). Its unlikely that with the faults you have described that you will get two-way comms between all matrices
Then work on getting ring A to work properly. Only when it does, you can start connecting ring B back. That way you can make sure there is nocrossover. Finally get the fibre RX /TX labelled accordingly.
The customer shouldalso make sure they connect ring A in direction 1 > 2 > 3 > 4 > 1 and ring Bin direction of 1 > 4 > 3 > 2 > 1. Otherwise the fibre loopback will notwork.
Customer reply: Fixed,You are right !
Both ring was 1>2>3>4
it's Ok now.