Wireless: When using two (2) PRO850s (Master+Slave) together, do all eight (8) beltpacs need to be addressed from the same configuration window, or are they broken up (4 and 4)?

Wireless: When using two (2) PRO850s (Master+Slave) together, do all eight (8) beltpacs need to be addressed from the same configuration window, or are they broken up (4 and 4)?

Beltpacs are always configured from the Master. Make any beltpac settings changes including frequencies on the master and connect to the Master for programming. Once your beltpac settings are made and saved on the Master, be sure to execute the “Sync Bases” command on the Master (PC850 Configure Tab, System Settings). This will update the slave with the beltpac settings information that it needs and verify the data communication connection between the bases. Then save the Slave settings again. You will be able to view the status of all eight beltpacs at once on the status page from the Master.

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.