Matrix: Connecting the Eclipse AES-6 interface connected to 3rd party AES networks

You can connect a Vseries panel over a 3rd party AES network. Like Lawo, SSL, Studer, Euphonix etc..Using this application allows the intercom panel to piggy-back over the AES-3 digital networkExample in a OB van fitted with an Eclipse matrix, you can have remote external panels connected via the Sound desk stage box which is located inside the stadium that the OB Van has parked next to.
At the Eclipse matrix end you need a AES-6 card set into 3rd party mode.(dip switch on the front of the card)At the Remote end you need a Vseries panel fitted with the AES-3 daughter card. The connection back over the AES-3 network can be with RJ45 (digital) or coax cable.
If using the AES-6-CX (coax) option then port 1 of the card needs to be connected to the AES-3 netowrk or a 75 ohm termination needs to be placed on port 1. As the whole card syncs of port 1. If there is no connection or termination then the other port 2-6 will not connect. (note this only applies to the AES-6-CX card) the requirement for a connection or termination is not required when using the AES-6-RJ card) 
For more details on the AES-6 card visit the Clear-Com web site 
See other solutions about the AES-6 card

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.