Matrix: Troubleshooting Matrix +3 frame serial connections
Matrix: Troubleshooting Matrix +3 frame serial connections
Question: I am trying to connect to my Matrix 3 Compact 72 frame using a serial connection. I'm using the Matrix Plus 3
version 2.4.1 software. I "run as" the program as Administrator. When I try to go on-line to the Matrix from the software I get
a "Frame is not responding check serial port" error message.
I notice that the Com Port settings on the PC are 9600 baud etc. but the PC Settings in the software are set to 57600 and not
changeable. I assume I need to use an ordinary non-proprietary male/female serial cable.
Answer: I would suggest that you double check the following:
1.) Matrix +3 frame, reseat the config-1 card if possible and power cycle frame
2.) PC should be Windows XP or lower as the software is based on 32 bit systems
3.) PC serial port should be set to Com 1, 2, 3 or 4, PCs with higher com ports cannot be recognized by PGM-Win software
4.) Verify in Windows Control panel / System / Hardware that the selected com port is available and has no issues
5.) PC serial port settings, Baud rate: 9600, Data Bits: 8, Parity: None, Stop Bits: 1, Flow Control: None
6.) Check the serial cable, it should be pin for pin cabling
7.) If you are using a USB to serial port adapter make sure the drivers for the adapter are installed on the PC
version 2.4.1 software. I "run as" the program as Administrator. When I try to go on-line to the Matrix from the software I get
a "Frame is not responding check serial port" error message.
I notice that the Com Port settings on the PC are 9600 baud etc. but the PC Settings in the software are set to 57600 and not
changeable. I assume I need to use an ordinary non-proprietary male/female serial cable.
Answer: I would suggest that you double check the following:
1.) Matrix +3 frame, reseat the config-1 card if possible and power cycle frame
2.) PC should be Windows XP or lower as the software is based on 32 bit systems
3.) PC serial port should be set to Com 1, 2, 3 or 4, PCs with higher com ports cannot be recognized by PGM-Win software
4.) Verify in Windows Control panel / System / Hardware that the selected com port is available and has no issues
5.) PC serial port settings, Baud rate: 9600, Data Bits: 8, Parity: None, Stop Bits: 1, Flow Control: None
6.) Check the serial cable, it should be pin for pin cabling
7.) If you are using a USB to serial port adapter make sure the drivers for the adapter are installed on the PC
, multiple selections available,
Related content
Matrix: New Install - How to Connect EHX to Eclipse Frame
Matrix: New Install - How to Connect EHX to Eclipse Frame
More like this
Matrix: What Trunking options are available on linked Eclipse frames?
Matrix: What Trunking options are available on linked Eclipse frames?
More like this
Matrix: New Eclipse Installation with AES67
Matrix: New Eclipse Installation with AES67
More like this
Matrix: How do I find the Dongle ID on an Eclipse Frame for passcode generation?
Matrix: How do I find the Dongle ID on an Eclipse Frame for passcode generation?
More like this
Matrix: Does EHX software / firmware support older Clear-Com Legacy panels?
Matrix: Does EHX software / firmware support older Clear-Com Legacy panels?
More like this
Netgear M4350-40X4C (XSM4344C)
Netgear M4350-40X4C (XSM4344C)
More like this
CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT
This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..
The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.