Partyline: How much current do RS700 beltpacks use compared to RS600

RS700 wired BPs use about 50% less current than RS600 wired BPs 

RS-601 26mA Quiescent / 30mA average talk / 50mA talk with signalling 

RS-602 55mA Quiescent / 62mA average talk, both channels simultaneously / approx: 105mA talk with signalling, both channels simultaneously 

RS-603 55mA Quiescent / 62mA average talk, both channels simultaneously / approx: 105mA talk with signalling, both channels simultaneously

RS-701 13mA Quiescent / 24mA Average talk / 28mA Talk with signalling 

RS-702 25mA Quiescent / 35mA Average talk / 40mA Talk with signalling

RS-703 25mA Quiescent / 35mA Average talk / 40mATalk with signalling

 

 

 

 

 

 

 

 

RS-601

26mA Quiescent

50mA average talk with signalling

RS-602

55mA Quiescent

62mA average talk with signalling both channels simultaneously

approx: 105mA talk with signalling, both channels simultaneously 

RS-603

55mA Quiescent

62mA average talk with signalling both channels simultaneously

approx: 105mA talk with signalling, both channels simultaneously 

RS-701

13mA Quiescent

24mA average talk

28mA average talk with signalling

RS-702

25mA Quiescent

35mA average talk

40mA average talk with signalling

RS-703

25mA Quiescent

35mA average talk

40mA average talk with signalling

 

The FSII Base II can provide power directly to the Partyline system and power a number of RS701 beltpacks directly

FreeSpeak II base II power : Supply = 400 mA to Partyline shared between A/B and C/D.

Approximately 14 RS 701 beltpacks per pair of ports
Approximately 10 RS 702 beltpacks per pair of ports
Approximately 10 RS 703 beltpacks per pair of ports

 

 

Solution update Jul-2021

FSE-BASE (Edge base station ) can provide power directly to the Partyline system and power a number of RS701 beltpacks directly

FSE-BASE power : Supply = 560 mA to Partyline shared between A/B and C/D.

Approximately 20 RS 701 beltpacks per pair of ports
Approximately 14 RS 702 beltpacks per pair of ports
Approximately 14 RS 703 beltpacks per pair of ports

 

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.