Partyline: Can I use the Gateway product with a PL system and still trigger the radio using Call signal?

Partyline: Can I use the Gateway product with a PL system and still trigger the radio using Call signal?

Solution dated 23-Mar-15One of our dealers asked if the Gatewayproduct could have a dedicated 2w PL interface?  The only option at the moment that I can think of would be touse a 2/4wire interface like the EF-701M As that would allow the 2w call signal to trigger the PTT on thegateway,- You are correct you can use aEF-701M to convert the 2-wire to 4-wire and the call signal will trigger thePTT.- You can also do VOX triggering keying with theCC-Gateway.  

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.