Question: I have a 2 year old Omega or Median frame with one defective power supply that needs to be replaced. Can I replace just the one defective supply or do both need to be replaced?
Answer: Both the Omega / Median series Eclipse frames were fitted with a universal PSU (part number #720379Z) at the start of December 2009. These universal PSUs can be identified by the silk-screening on the front panel of the PSUs, each new type PSU will say PART No 720379Z. These part number PSUs can be replaced singularly.
Older Omega frames will have PSUs with an internal sticker fitted: 740101Z for Eclipse Omega (15 slot). Do not fit into any other Matrix type. If one of these PSUs fails they will need to be replaced in pairs with the current 720379Z PSU as the older Omega PSU is no longer available.
Older Median frames will have PSUs with an internal sticker fitted: 740134Z for Eclipse Median (7 slot). Do not fit into any other Matrix type. if one of these PSUs fails they will need to be replaced in pairs with the current 720379Z PSU as the older Median PSU is no longer available.
The old Omega and Median PSUs are not repairable and need to be replaced with the new 720379Z universal PSUs.
Related content
CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT
This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..
The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.