Partyline: Can I disable the MT-1 input/output terminations?
Partyline: Can I disable the MT-1 input/output terminations?
The MT-1 needs the internal terminationson the PCB because the transformers on the MT-1 can become unstable if theterminations are removed, thus it is NOT RECOMMENDED to remove the terminations on the PCB. When using an MT-1 turn off the termination at the PL mainstation or PL power supply. If the termination is in let’ssay a Cellcom base station where the termination is permanent, still disable thetermination in the unit and not at the MT-1.
Use only one MT-1 per PL channel, the use of more than one will result in a double termination / lower audio level on the channel.
The MT-1 unit is used to provide isolation between two powered PL systems where you have issues with ground loops or earth hum
Use only one MT-1 per PL channel, the use of more than one will result in a double termination / lower audio level on the channel.
The MT-1 unit is used to provide isolation between two powered PL systems where you have issues with ground loops or earth hum
, multiple selections available,
Related content
Partyline: Can I disable the termination on a PK-7 power supply?
Partyline: Can I disable the termination on a PK-7 power supply?
More like this
Partyline: Does the MT-1 require power on both sides in order to function properly?
Partyline: Does the MT-1 require power on both sides in order to function properly?
More like this
Partyline: What is the purpose of "Termination" on a PL channel?
Partyline: What is the purpose of "Termination" on a PL channel?
More like this
Partyline: What functions do the jumpers inside the MT-701 support?
Partyline: What functions do the jumpers inside the MT-701 support?
More like this
Partyline: MT 701 - Audio not passing through from A to B
Partyline: MT 701 - Audio not passing through from A to B
More like this
Partyline: Does the MT-1 come in an optional enclosure with XLR connectors?
Partyline: Does the MT-1 come in an optional enclosure with XLR connectors?
More like this
CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT
This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..
The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.