Partyline: Can I disable the MT-1 input/output terminations?

The MT-1 needs the internal terminationson the PCB because the transformers on the MT-1 can become unstable if theterminations are removed, thus it is NOT RECOMMENDED to remove the terminations on the PCB.   When using an MT-1 turn off the termination at the PL mainstation or PL power supply. If the termination is in let’ssay a Cellcom base station where the termination is permanent, still disable thetermination in the unit and not at the MT-1.
Use only one MT-1 per PL channel, the use of more than one will result in a double termination / lower audio level on the channel.

The MT-1 unit is used to provide isolation between two powered PL systems where you have issues with ground loops or earth hum

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.