Matrix: How do I wire up two FIM-202s to support remote Matrix panel operation?

Matrix: How do I wire up two FIM-202s to support remote Matrix panel operation?

To properly setup a remote panel using FIM-202s there will need to be one FIM-202 at the frame end and one FIM-202 at the remote panel location.
At the frame end connect a standard CAT-5 cable to one of the two Matrix connections on the FIM-202 and the other end to the frame port.
At the remote panel end connect a standard CAT-5 cable to one of the two Station connections on the FIM-202 and the other end to the remote panel matrix connection.
The two FIM-202s will need to be connnected together by a pair of fiber cables for single mode operation (TX connected RX using standard ST connectors on 8 micron diameter cable in each direction). This will allow the two FIM-202s to be remoted from each other up to 12 miles maximum. (see attached diagram below for connection details)
In this configuration two remote panels can be connected to the Eclipse / Matrix frame using two frame ports. The FIM-202s are transparent to the frame so no special configuration of frame software is required.
Each FIM-202 location requires a wall wart PSU unit that is 110VAC compliant.

FileModified
FIM-202 connection diagram.pdf
FIM-202 connection diagram.pdf
Apr 6, 2019 by Administrator

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.