Wireless: Mulit-linked Tempest 2400 system troubleshooting tips
Trouble shooting tips for a Tempest multi-linked system
Onsite issues1) 6 Base Stations linked together via Zsync2) 2.4 GHz3) Using Channel D multiplexer w/Directional antennas4) Dinosaur controls use static 2.4 also5) Can’t seem to get farther than 30feet from antennas w/ BPs
Troubleshooting tips 1) Check Radio versions...make sure all radios for base stations and beltpacks are v1.18
2) Need to assure all Net #s are 0-10, and not separated by 4 like we used to say3) Check for different lockout keys,each base4) Check all base stations are on the same firmware version 3.0.0 or later, Check all beltpacks are on the same firmware version5) If base starions have different firmware versions place highest versions at top tochain, descending6) Turn on one at a time and see where RF saturation / errors occurs7) Verify that the Zsync dongle is plugged into the first base station in the string of base stations