Matrix: What are the EHX Software System Limits?

Matrix: What are the EHX Software System Limits?

 

 

Solution update Aug 10, 2026

For EHX v15.0

Configuration Item

Limit (Max. Number)

Configuration Item

Limit (Max. Number)

Fixed Groups

999 (across whole linked set)

Partylines

399 (across whole linked set)

Partyline members

64

IFBs

200

GPSF (General Purpose Special Functions)

3200

These are Allocated by macros and controls. 3 GPSFs are used for a control.

Capacity information is available in Diagnostics > Resource Chart > GPSF (hover over chart item for exact figures).

Controls

999

Physical ports

496 (36 on Eclipse HX-PiCos)

Beltpacks registered to the system

320

Number of beltpacks actively in use

Combination of FS II, Icon and Edge: 255 max;

FS Cell: 320 max

Roles

424 max (according to resource allocation, set in Preferences > Matrix Settings > Common Resources). Default: 300

Number of roles in a role team

150

Matrices in a linked group

64

Keys

249,600

Key Groups

100 (across whole linked set)

Sort Groups

64 per frame

Agent-IC clients per frame

255

Station-IC clients per frame

255.

If Station-IC is licensed locally, the maximum per frame is 320.

Matrix entity aliasing

 

496/1024. Maximum aliases in a linked set system is 496. From Eclipse v14 and above, the limit increases to 1024. Additional aliases are stored in volatile memory and are lost on matrix reset. Enabled by editing the EHX.xml configuration file.

 

Hardware Power Limits (dated Aug 10, 2026 )

Hardware limits vary depending on:

  • Matrix type

  • Card type

  • PSU type (One/Bel Fuse PSU 720379Z recommended)

  • Overall system usage

For precise calculations, use the Eclipse HX System Power Calculator available from the Clear-Com website and Solution Finder.

As a rough estimate, matrices support the following number of high-power cards:

Matrix Type

Maximum High-Power Cards

Matrix Type

Maximum High-Power Cards

Omega

5 standard
Up to 7 E-IPA cards (subject to Omega E-IPA High Power Mode criteria)

Median

4

Delta

3

High-Power Card Types

High-Power Cards

High-Power Cards

E-IPA

IVC-32

E-Que

LMC-64

System Behavior When Limits Are Exceeded

Condition

System Response

Condition

System Response

High-power card limit exceeded

CPU services only the supported number of cards, beginning with the lowest slot numbers

Power limits breached

System alerts generated and event log messages recorded

Ongoing power-limit condition

Warning message written to the event log every 10 minutes

Attempt to install additional high-power card beyond limit

Warning message displayed during configuration

 

 

 

==========================================================================================================

The following programming limits are shown for Eclipse HX v7.5.0 software going forwards:  It could be very helpful on larger systems when setting up EHX system parameters.

EHX 7.5.0 Software Limits



The maximum number of ports is 496  for Omega / Median / Delta matrices  (36 for Pico-HX) For  Omega / Median / Delta matrices different card types use different port counts 















CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.