Matrix: Why Matrix using old PSU resets after installing a new card?
Matrix: Why Matrix using old PSU resets after installing a new card?
On a recentcommissioning, an AE encountered an issue related to old power supplies. Here’re the details: - Median installed abouteight years ago with two CPUs, four MVX cards, 1 EQUE for FS. - upgrade matrix from EHX7.0 to 8.5.2, which went well- Installed a new IVC-32 card andsoon after we realized the customer couldn’t do a simple “Apply Changes”, theywould get an error. During the troubleshooting process one of the powersupplies quit working, so we only had one power supply for the wholesystem. At this point, the system stated resetting every couple ofminutes. After some research, we learned the old power supplies did not supplyenough power for this combination of cards.
To stabilize the system, wehad to remove the IVC and one CPU. The old PSUs were dated 2007 PN: 740134Z
We ordered two new powersupplies and the system is OK.
Clear-Com recommends all customer use PSUs PN: 720379Z in their Omega and Median frames
To stabilize the system, wehad to remove the IVC and one CPU. The old PSUs were dated 2007 PN: 740134Z
We ordered two new powersupplies and the system is OK.
Clear-Com recommends all customer use PSUs PN: 720379Z in their Omega and Median frames
, multiple selections available,
Related content
Matrix: Eclipse Omega / Median matrix PSU - replacement
Matrix: Eclipse Omega / Median matrix PSU - replacement
More like this
Matrix: MTX+3 system loses configuration after swapping CPU battery
Matrix: MTX+3 system loses configuration after swapping CPU battery
More like this
Matrix: Eclipse matrix not keeping the configuration when I power off the matrix (battery back up)
Matrix: Eclipse matrix not keeping the configuration when I power off the matrix (battery back up)
More like this
Matrix: Matrix + III frame shows odd intermittent behavior with panels going offline
Matrix: Matrix + III frame shows odd intermittent behavior with panels going offline
More like this
Matrix Eclipse Median CPU start up problem
Matrix Eclipse Median CPU start up problem
More like this
Matrix: How do I tell the Difference Between Median and Omega power supplies?
Matrix: How do I tell the Difference Between Median and Omega power supplies?
More like this
CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT
This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..
The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.