IP: What are the port settings for Eclipse and Drake panels when using Voice2
The Voice2 unit can carry 4 x audio and 4x data channels over IP Each channel is presented on a pin RJ45 connector on the rear of the unit.Each RJ45 supports RS422 data and Analogue (line level) 0db audio.
► RS-422 data attributes supported Baudrates: 110, 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200Databits: 5, 6, 7, 8Parity:None, Odd, EvenStopbits: 1 or 2Flowcontrol: None or XON / XOFF Clear-Com / Eclipse panels use 19200, N, 8, 1
Drake/Cmapsi 4000 panels uses 9600, N, 8, 1 The RJ45 ports can be used to connect Clear-Com
panels or other3rd party devices that need to transport
data