IP: What are the port settings for Eclipse and Drake panels when using Voice2

The Voice2 unit can carry 4 x audio and 4x data channels over IP Each channel is presented on a pin RJ45 connector on the rear of the unit.Each RJ45 supports RS422 data and Analogue (line level) 0db audio.
► RS-422 data attributes supported Baudrates: 110, 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200Databits: 5, 6, 7, 8Parity:None, Odd, EvenStopbits: 1 or 2Flowcontrol: None or XON / XOFF  Clear-Com / Eclipse panels use 19200, N, 8, 1
 Drake/Cmapsi 4000 panels uses 9600, N, 8, 1 The RJ45 ports can be used to connect Clear-Com
    panels or other3rd party devices that need to transport
   data

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.