Matrix: Can I connect both Helixnet and Vpanels via LQ to a Matrix

Matrix: Can I connect both Helixnet and Vpanels via LQ to a Matrix

Would it be possible to connect a couple of 4wires from a Helixnet and a couple of Vseries panels to an 8 port LQ box, and bring them out on another 8 port LQ connected to a Delta frame MVX card More interested if I can mix panels with 4wires on the LQ.
SolutionSimple answer is Yes  You need an LQ at each end Connect the Helixnet and Matrix MVX ports into a LQ channel Connect the Panel and Matrix MVX ports into a LQ DIRECT Note: There are variations using IVC card, in which case you only need 1x LQ at the Remote Helixnet location, as the remote V-series Panels and the LQ unit can connect directly to the IVC card 

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.