HelixNet: Do I need to supply IP addresses to each IKB-12 panel connected to an HMS-4X main station?

Each IKB-12 user panel connected to an HMS-4X main station running v2.1 firmware will require its own IP address
on the system. 
To set the IP address on a HMS-4X Mainstation
To set addressing on the HMS-4X main station go to the web browser and set the IP address found
from the HMS-4X local menus. or use the front panel menu
To set the IP address on a IKB-12 user panel
Press and hold the rotary control on the front panel of the KB Station for four seconds, and then select Networking >
Preferences > DHCP > Disable.  From Networking > Preferences, set the IP Address, Gateway and Subnet mask to
the required settings. 
You must now reboot the Industrial KB Station. Select Administration > Reboot > Reboot Now.  If your network contains
only one HelixNet Main Station, the Industrial KB Station automatically pairs with the Main Station.
If there is more than one Main Station, press and hold the rotary control on the front of the KB Station for four seconds,
and then select Networking > Pair to Station > By Name, and select the name of the required Main Station.

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.