Question:  I upgraded my Tempest 2400 system from version 2.10 to version 3.0 to take advantage of the seamless roaming feature.  After upgrading the system components (base station and beltpacks) I am having some issues trying to setup roaming on the beltpacks.  They won't setup check marks on the enable roaming option.  Am I doing something incorrectly?
Answer:  We recommend that after upgrading Tempest base stations and beltpacks to version 3.00 that the user initiate a "Clear Memory" and "Factory Default" in the Tech Menu on all beltpacks and base stations.  After performing the Clear Memory option the user will have to reset the following functions on the system:
A.  Reset the Base station Network #
B.  Reset the Base station Lockout #
C.  Reset the Base station LAN settings
D.  Repair all Beltpacks to their respective Base stations
Once these settings are re-initiated the roaming features on the beltpacks can be accessed correctly. 
A complete guide to upgrading Tempest systems to version 3.00 is attached below. 
  File Modified

PDF File Instructions_Tempest_3 0_Codeupdater_rev2.pdf Instructions_Tempest_3 0_Codeupdater_rev2.pdf

Apr 06, 2019 by Administrator

Related content

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.