Partyline: MS-702 main station displays false call signal indication when connected to CCI-22 interface card

Question:  I have a CCI-22 card that is generating a false call signal indication to a MS-702 party-line main station.  When I remove the CAT-5 cable from the CCI-22 to the Eclipse frame the call signal indication goes away.  I've applied a RED reset to the Eclipse frame, but the tally is always there.  We did have an initial issue with the CCI-22 to MS-702 linking cable being mis-wired, but that was fixed.  All the Eclipse panels have no active keys set to the CCI-22 and auto signal isn't active.  Is the CCI-22 defective / bad? 

Answer:  The first thing to try is a BLACK reset on the Eclipse frame, it is entirely possible due to the miswired cable connecting from the CCI-22 to the MS-702 that a false call signal was generated and the Eclipse port is stuck generating a false call signal.  Initiating a BLACK reset will reset the frame and reset all active crosspoints / signalling to their inactive state coming from the Eclipse frame. 
Select Apply changes > select options > select the clear-frame data check box (this will also check the reset frame box as well) 


CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.