/
Partyline: I need to replace an MX-840 source/destination assignment panel, how many RCS-2700s do I need?
Partyline: I need to replace an MX-840 source/destination assignment panel, how many RCS-2700s do I need?
Question: I have to replace an old MX-840 assignment panel with 10 sources / 40 destinations, will one RCS-2700 assignment panel perform the functions of the old MX-840?
Answer: Up to six RCS-2700 units can be wired together in various combinations for up to a 15-source by 72-destination system. There are six possible combinations of units. A single RCS-2700 unit has 8 sources of audio and 24 remote destinations, as shown in the figure below.

Two RCS-2700 units can be connected together to provide either 15 sources of audio and 24 destinations or 8 sources of audio and 48 destinations as shown below. The address switch on the rear panel of each unit must be set with the
correct unit number to determine which configuration is chosen.

Other possible configurations include: 15 sources and 48 destinations (4 units), 8 sources and 72 destinations (3 units), and 15 sources and 72 destinations (6 units).
Answer: Up to six RCS-2700 units can be wired together in various combinations for up to a 15-source by 72-destination system. There are six possible combinations of units. A single RCS-2700 unit has 8 sources of audio and 24 remote destinations, as shown in the figure below.
Two RCS-2700 units can be connected together to provide either 15 sources of audio and 24 destinations or 8 sources of audio and 48 destinations as shown below. The address switch on the rear panel of each unit must be set with the
correct unit number to determine which configuration is chosen.
Other possible configurations include: 15 sources and 48 destinations (4 units), 8 sources and 72 destinations (3 units), and 15 sources and 72 destinations (6 units).
, multiple selections available,
Related content
Partyline: RCU-67 programmer for RCs-2700 assignment panel now obsolete
Partyline: RCU-67 programmer for RCs-2700 assignment panel now obsolete
More like this
Partyline: Can I control the source/destination programming of an RCS-2700 via a PC and RCU-67 remote programmer at the same time?
Partyline: Can I control the source/destination programming of an RCS-2700 via a PC and RCU-67 remote programmer at the same time?
More like this
Partyline: Is the RCS2700 source/destination assignment panel compatible with RTS TW products?
Partyline: Is the RCS2700 source/destination assignment panel compatible with RTS TW products?
More like this
Partyline: Does the RCS-2700 have a default preset configuration?
Partyline: Does the RCS-2700 have a default preset configuration?
More like this
Matrix: How many I-Station expansion panels are supported in ECS 5.1?
Matrix: How many I-Station expansion panels are supported in ECS 5.1?
More like this
Digital Partyline: How many HKB-2X speaker stations can be connected over Ethernet to a Helixnet main station?
Digital Partyline: How many HKB-2X speaker stations can be connected over Ethernet to a Helixnet main station?
More like this
CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT
This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..
The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.