Matrix: Does EHX software / firmware support older Clear-Com Legacy panels?
Question: I have some existing ICS-1016E panels that I need to add to a new Pico frame, but I noticed that my Eclipse HX software doesn't show those panels in the "port function" under "Cards and ports". My only options are I-station and the V-series panels. How do I add these ICS panels?
Answer: HX versions of Eclipse only supports i-stations and v-series panels (rotary, pushbutton and lever key).
Clear-Com legacy panels (ICS-92, ICS-1016, ICS-2003, PD42xx) do not work with HX, only with standard ECS Eclipse enabled frames.
solution update May 5, 2017
following the release of EHX v9.0 , ICS-22 , ICS-1008E / 1016E are now supported in EHX and can be connected to HX enabled matrices running EHX v9.0 or later
Related content
CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT
This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..
The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.