Problem:A panel key and a matrix GPI trigger the same control. The control triggers a route and a GPO.
The GPI is activated and the route and GPO are triggered. 
The panel key is pressed. No change, the route and GPO are still made.
The panel key is unlatched. The route is broken and the GPO released.
NB: This issue is fixed in later versions after EHX v8.5

Solution:A workaround for this is to use two extra controls and a logical OR gate.
Make a control for the panel key.
Make a control for the GPI.
Use Logic Maestro to OR the two new controls and output to the original control.
Attached is the necessary logic.


Keywords: Unlatch, GPIO, trigger, 
  File Modified

File 3562_OR_two_controls_to_trigger_a_GPO_control.ccm OR_two_controls_to_trigger_a_GPO_control.ccm

Apr 06, 2019 by Administrator

File 8979_Control logic OR.JPG Control logic OR.JPG

Apr 06, 2019 by Administrator

File Control logic OR.JPG Control logic OR.JPG

Apr 06, 2019 by Administrator

File OR_two_controls_to_trigger_a_GPO_control.ccm OR_two_controls_to_trigger_a_GPO_control.ccm

Apr 06, 2019 by Administrator

Related content

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.