Wireless: I get a "system busy" prompt when we try to talk from a beltpack on a DX beltpack.

Wireless: I get a "system busy" prompt when we try to talk from a beltpack on a DX beltpack.

There are a couple of reasons for a system busy prompt. The first one would be because you have exceeded the talk back path capacity of the base. The DX100, DX200, DX210, DX300, DX410 have a maximum limit of 4 wireless talk back paths. The 5th user will have to wait until one of the first come first serve 4 user unlatches from one of the talk back paths. If the DX210, DX300, DX410 is in dual mode the talk back paths are reduced to a 3 max limit.
Other reasons could be degraded RF transmission due to multi path conditions or being too far from the base. 

Related content

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.