Question:  I want the ability to disable the Loud Speaker cut control on a V-Panel (lock the speaker on so it can't be accidently pressed on by the panel operator when they are adjusting the volume levels).  Can this be done using Logic Maestro logic symbols in ECS?
Answer:  Enable Logic Maestro in ECS.  Follow these steps to lock the speaker LS cut on a V-Panel in the speaker permanently enabled mode:
1.  From the palette drag in the logic latch and panel control symbols into the main work area
2.  Connect the (Q) latch output to the panel control input
3.  Set panel control parameters as follows:
     a.  Loud Speaker cut
     b.  Permanent Override of Local
4.  Drag the specific V-panel from the left-hand side to the panel control symbol.  See diagram below.  

















5.  Click on the "Simulate" button to verify the operation of the logic maestro diagram
6.  Click on "OK" to save the diagram, then set a check mark on the Enabled box and download to ECS.  
7.  Speaker on the selected V-Panel is now permanently enabled, pressing on the LS cut / volume control will have no effect

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.