Wireless: FreeSpeak II Beltpack Site Survey Mode explanation of metrics




Note: Site Survey – BP CONNECTED TO A SYSTEM
Note: This requires that the FS II beltpack have full (Advanced) menu access set in EHX software or Config Editor software (or you have to locally give it access in the Settings/Admin Options menu, with the menu code {set in the software}  at the BP and then enable full menu access if the BP has limited access)
Note: This option is only available if the BP is connected to a system (referred to as the current system)
Note: The A & B talk keys will operate as normal when in this mode
To access site survey mode place the beltpack into master menu mode / scroll to "Site Survey" then press the "D" button to enter
Display lists all visible RFPs (Transceiver Antennas) ONLY connected to the current system
Shows 2 digit RPN number only (To get antenna # subtract 5 from the RPN).   The Current Antenna is shown at the top of display.
NOTE: the top line is displaying the TCVR info that the BP is now connected to.
The second line displayed (above picture 10 & 50) is a second antenna in this system reporting its RSSI. If other TCVRs (antennas) were active, you’d see them as well. (As below)



This solution is also attached as a word document below.







  File Modified

Microsoft Word 97 Document FreeSpeak II Beltpack Site Survey Mode explanation of metrics.doc FreeSpeak II Beltpack Site Survey Mode explanation of metrics.doc

Apr 06, 2019 by Administrator

PNG File image-20211103-152246.png

Nov 03, 2021 by ernie addow

PNG File image-20211103-152401.png

Nov 03, 2021 by ernie addow

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.