HelixNet: How do I wire a HelixNet Base 2W module to a BTR-800 Wireless base station 2W interface?
HelixNet: How do I wire a HelixNet Base 2W module to a BTR-800 Wireless base station 2W interface?
Question: I have recently purchased a Helixnet system with two HLI-2W2 Modules. I am trying to get analog clear com format out of the 2 wire
Into a Telex BTR 800 unit. Do you have any advice on this topic?
Answer: The HelixNet 2W module and BTR-800 2W interface both require a Clear-Com party-line power supply (PS-702 or PS-704) or main station connection (MS-702 or MS-704) to provide the 30 Vdc for the HelixNet and BTR interfaces and to provide the 200 ohm termination for the PL channel. This information also applies to the Clear-Com WBS-670 and WBS-680 wireless intercom base stations. Attached below is a picture of a typical setup between the HelixNet base with a 2W module to a WBS-680 / BTR-800 wireless base station.

Into a Telex BTR 800 unit. Do you have any advice on this topic?
Answer: The HelixNet 2W module and BTR-800 2W interface both require a Clear-Com party-line power supply (PS-702 or PS-704) or main station connection (MS-702 or MS-704) to provide the 30 Vdc for the HelixNet and BTR interfaces and to provide the 200 ohm termination for the PL channel. This information also applies to the Clear-Com WBS-670 and WBS-680 wireless intercom base stations. Attached below is a picture of a typical setup between the HelixNet base with a 2W module to a WBS-680 / BTR-800 wireless base station.
, multiple selections available,
Related content
HelixNet: What is the PoE specification of HelixNet?
HelixNet: What is the PoE specification of HelixNet?
More like this
Digital Partyline: What is the PoE specification for Helixnet devices
Digital Partyline: What is the PoE specification for Helixnet devices
More like this
Wireless: Dx-300 (MB300) base station linking considerations
Wireless: Dx-300 (MB300) base station linking considerations
More like this
Encore: Can I power a RS-701 from a KB702GM
Encore: Can I power a RS-701 from a KB702GM
More like this
HXII-DPL Powerline Device - "Getting it Going"
HXII-DPL Powerline Device - "Getting it Going"
More like this
HXII-DPL Powerline Device-Frequently Asked Questions
HXII-DPL Powerline Device-Frequently Asked Questions
More like this
CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT
This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..
The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.