Drake 4000: Registering CellCom CEL-BP Beltpacks with CMAPSi.

In order to register the cellcom bps with CMAPSi check the following:
Go to cmapsi , selectcomms Ethernet .
Check that the cnetio.ini file which islocated in program files > cmapsi contains the following section: [freespeak]
BAUD=19200                                                ; 300 600 1200 2400 9600 19200
PORT=1                      ; 1 2 3 4
PARITY=N                                                         ; N E O M S
DATABITS=8                                               ; 7 8
STOPBITS=1                                               ; 1 2
RTSFLOW=0  Make sure that the port number corresponds to the correct serial port number in the PC. We recommend the use of BP with firmware v142 for cmapsi users .. anything later and the settings in cmapsi may nottake properly ,. .but later versions have also been used by customers.

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.