HelixNet: HMS-4X main station connections to Tempest via 4W or 2W

HelixNet: HMS-4X main station connections to Tempest via 4W or 2W

Tempest to HelixNet via 4-wire (note no software re-pining on 4W ports) so use audio x-over CAT-5/6 cable.














Tempest to HelixNet via 2-wire








Note that you need to use a Clear-Com PL power supply / Main Station or put Tempest 2W ports into “Master Mode”
which sets termination and +24Vdc on 2W XLRs.

Related content

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.