Matrix: Can I trigger an alarm from the Eclipse Median/Omega frame from a PSU-101 with a power supply issue?
Matrix: Can I trigger an alarm from the Eclipse Median/Omega frame from a PSU-101 with a power supply issue?
Question: I have a Median frame in one room and a PSU-101 / IMF-3 frame with interfaces located in a adjacent equipment room. I would like the Median frame to trigger its external alarm if the PSU-101 experiences an issue with its power supplies, can this be done with a wired connection from the PSU-101 alarm contacts to the Median frame external alarm contacts?
Answer: The Median frame can support external alarm contacts from a PSU-101 power supply see the wiring diagram below for the pin outs from the Median frame external alarm DB-9 connector and the PSU-101 4-pin Jones type connector on the rear of the power supply:

Pins are provided for adding an additional alarm source to the matrix’s alarm system. Pin 6 is an alarm input to the Eclipse Median matrix. It is connected to the input of a 3.3 V logic device. A logic high on this input will cause the Eclipse Median to detect an alarm condition. A logic low or an open circuit will cause the Eclipse Median to detect no alarm condition.
Pin 1 is a voltage source out of the Eclipse Median matrix. It is connected through a 10K Ohm pull-up resistor to the +5 V supply rail inside the Eclipse Median matrix. A contact closure placed across pins 1 and 6 will also cause an alarm condition. The alarm outputs of the PSU-101 power supply could be wired directly to these pins allowing the CPU card to report PSU failures also.
Answer: The Median frame can support external alarm contacts from a PSU-101 power supply see the wiring diagram below for the pin outs from the Median frame external alarm DB-9 connector and the PSU-101 4-pin Jones type connector on the rear of the power supply:
Pins are provided for adding an additional alarm source to the matrix’s alarm system. Pin 6 is an alarm input to the Eclipse Median matrix. It is connected to the input of a 3.3 V logic device. A logic high on this input will cause the Eclipse Median to detect an alarm condition. A logic low or an open circuit will cause the Eclipse Median to detect no alarm condition.
Pin 1 is a voltage source out of the Eclipse Median matrix. It is connected through a 10K Ohm pull-up resistor to the +5 V supply rail inside the Eclipse Median matrix. A contact closure placed across pins 1 and 6 will also cause an alarm condition. The alarm outputs of the PSU-101 power supply could be wired directly to these pins allowing the CPU card to report PSU failures also.
, multiple selections available,
Related content
How to monitor HCI message for the Delta PSU?
How to monitor HCI message for the Delta PSU?
Read with this
Matrix: Can I sub in a PSU-101 in for a PSU-102 power supply used in a IMF-1 M+2 system?
Matrix: Can I sub in a PSU-101 in for a PSU-102 power supply used in a IMF-1 M+2 system?
More like this
Matrix: What do the Pico PSU alarm messages mean?
Matrix: What do the Pico PSU alarm messages mean?
More like this
Matrix: Do I need to replace Median / Omega frame PSUs in pairs?
Matrix: Do I need to replace Median / Omega frame PSUs in pairs?
More like this
VSeries Power Supply Pin-Out
VSeries Power Supply Pin-Out
More like this
Matrix: What is the ICS-2003 PSU connector wiring scheme?
Matrix: What is the ICS-2003 PSU connector wiring scheme?
More like this
CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT
This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..
The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.