Matrix: MADI phase boundary messages in Eclipse matrix event log

What does the MADI phase boundary message mean?


Boundary Phase message explanation:

MADI data is clocked asynchronously to the Sample Rate clock. The system uses the Sample Rate Clock ( Word Clock input to the MADI card ) input to mark the beginning of a new frame. E-MADI continually monitors the edges of the received MADI data signal and compares it with edges of the Sample Rate clock. Small adjustments are continuously needed to re-align to the Sample Rate Clock. When these re-adjustments are larger  the software reports them as a “Boundary Phase message” … with their adjustment value.


Messages in the range of +- 10 can be ignored.  Larger errors may indicate a slippage or delay between the MADI stream and the MADI card clock input.

 

Related content

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.