IP Products: Does LQ 3.0 connect directly to IVC-32 IP cards?
LQ 2-wire and 4-wire interfaces with version 3.0 firmware can now connect directly to IVC-32 IP cards in Eclipse HX
frames running version 8.7 or higher firmware. This allows users to connect a remotely base party-line system or
remotely based wireless base station or other 4-wire device to an Eclipse frame using a single LQ interface. Simply
open the LQ browser interface and point it to the Eclipse frame IVC-32 card's IP address / designated user ID and
password and make the channel assignment to create the audio channel.
LQ-4W interface to a wireless base station in a remote studio setting:
LQ-2W interface to a Clear-Com party-line comms system in a remote studio setting: