IP Products: What specific settings are available to the LQ-4WG2 interface?

IP Products: What specific settings are available to the LQ-4WG2 interface?

The LQ-4WG2 / LQ-R4WG8 / LQ-R2W4+4WG4 interfaces have some user specific settings that can be accessed
via the CCM web browser screen.  These settings are:
4-wire + GPIO specific settings
  • Output level: Mic Level (-55db)/Line Level (0 dB).
This setting is used when connecting to devices (like a hand-held radio) where audio connects directly to the mic.
Selecting Mic Level allows for extra noise on the line to be attenuated. This setting works in conjunction with the
Output Gain; overall gain = Output Level + Output Gain.

GPIO action triggers (4-wire + GPIO and IVC-32 ports)
  • GPI action trigger: Disabled/Channel Event 1/Channel Event 2/Channel Call Event (assign a Channel Logic Event on detection of a GPI signal).
  • GPO action trigger: Disabled/Channel Event 1/Channel Event 2/Channel Call Event (assign which Channel Logic Event triggers the GPO).
  • GPO Off Delay: None to 2 seconds. This sets a delay on the deactivation of the GPO after a Channel Event has disappeared.
  • Test: use to check that the GPO is firing (hardware).



















Looking for labels? They can now be found in the details panel on the floating action bar.

Related content

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.