Matrix: Mentor RG settings when used as a AES67 grandmaster clock

Matrix: Mentor RG settings when used as a AES67 grandmaster clock

Please see the Mentor RG user manual for full details. https://www.trilogycomms.com/en/assets/uploads/user-guides/assets/uploads/Mentor_RG_UserGuide_36090600.pdf( https://www.trilogycomms.com/en/support/user-guides )

Depending on your AES67 setup you might have to adjust some settings (see attached)
Mentor RG units curently (dated 2018) use 100Mb NICs, please ensure your Ethernet switch supports 100Mb connections 

The settings below have been tested on a Clear-Com AES67 network with our IP transceivers and E-IPA card
.note: The priority1 and priority2 parameters, it should be set to anything below 127 (which is the priority advertised by the E-IPA card) if you want the Mentor to be the grandmaster clock.   Does not necessarily need to be set to 64.































Generic PTP grandmaster clock settings
Parameter Proposed Value Comment Domain 0   Announce Interval 1 2 seconds Announce Receipt Timeout 3   Sync Interval -3 0.125 second Min Delay Request Interval 0 1 second

There are currently no attachments on this page.

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.