Partyline: Can I plug in a PTX-3 transmitter into a MS-704 PL channel?
Partyline: Can I plug in a PTX-3 transmitter into a MS-704 PL channel?
The PTX-3 is completely compatible with a party-line main station provided the dip switches on the rear of the PTX-3 are set to emulate the Clear-Com party-line 3-pin XLR intercom feed or set to emulate RTS channel 1 or channel 2. This will configure the PTX-3 to use its 3-pin XLR as follows:
Pin 1 = Ground
Pin 2 = +30 Vdc
Pin 3 = Audio at -10dbu
Set dip switch as follows for Clear-Com operation:
1, 2 and 3 to down position
4 to up position
Pin 1 = Ground
Pin 2 = +30 Vdc
Pin 3 = Audio at -10dbu
Set dip switch as follows for Clear-Com operation:
1, 2 and 3 to down position
4 to up position
, multiple selections available,
Related content
Wireless: How do I setup a connection from my CellCom base station to a MS-702 PL main station?
Wireless: How do I setup a connection from my CellCom base station to a MS-702 PL main station?
More like this
Partyline: Can I connect PL-Pro main stations to Encore PL main stations?
Partyline: Can I connect PL-Pro main stations to Encore PL main stations?
More like this
Wireless: Can I connect a DX-300 system directly to a MS-702 Partyline main station?
Wireless: Can I connect a DX-300 system directly to a MS-702 Partyline main station?
More like this
Partyline: Portable Encore PL system with 2-way radio access
Partyline: Portable Encore PL system with 2-way radio access
More like this
Partyline: Clear-Com TW partyline explanation
Partyline: Clear-Com TW partyline explanation
More like this
Partyline: How do I connect (extended) a PL system over fibre
Partyline: How do I connect (extended) a PL system over fibre
More like this
CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT
This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..
The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.