Helixnet : Helixnet system runing v3.1.46 firmware with HXII-BP
Since 3.1 Helixnet requires two firmware files on theMainstation, one for HXII-BP, one for everything else. When both files aredifferent, there is a warning on CCM and on the front panel of HMS-4X. Now with 3.1.46 in production, what can happen: HMS-4X in the field with 3.1.45.- connecting a new HXII-BP with 3.1.46 to a Helixnet base (running 3.1.45) the HXII-BP willnot downgrade to 3.1.45 AND will not complain aboutversion mismatch either- connecting any other Helixnet device running 3.1.46 to a HMS (running 3.1.45): The new Helixnet device will automatically update to 3.1.45 first time itconnects New HMX-4X with 3.1.46 sent out- Connecting any Helixnet device running 3.1.45 to a Helixnet base (running 3.1.46) , including any HXII-BP,will automatically update to 3.1.46 first time it connects Therefore, customers with 3.1.45 don’t have to update to 3.1.46. But anynew equipment they buy except HXII-BP will update first to 3.1.45.