Ihave set up an IFB and it works ok but I want a level control of the mix minus feed that is overkeyed.
If using the V-rotary panel - when you go into IFB assignment mode (by selectingthe COM button)
and you select IFB destination - any turn of the rotary encoder will adjust the IFBdestination output level
When you select the IFB source (mix-minus) then any turn of the rotary encoder willadjust the IFB source mix-minus input level
Note: if you open the ECS > diagnostic screen > crosspoint viewer youwill see the input / output level changes that you have made
remember in the crosspoint viewer screen the inputs are on the left and theoutputs are across the top