IP-Voice: Voice units locking up
IP-Voice: Voice units locking up
Customer Voice units locking up on private VPN link.running firmware v2.0.5
SolutionAfter checking the settings on the voice units it was found
That on the client unit, 2 channels had the jitter buffer min set to 0, perhaps making it 20 would helpA simple way to check the min / max jitter settings is to ping the voice unit from your PC and see the resultant ping values add an over head of 20-40ms to both the min and max values shown on your PC..
Other possible solutions a) Trace level set too high: Go to Config> admin> log screen and ensure the trace level is set to 1 or 2 .... the higher the trace level (max level is 4) the more higher the CPU utilisation which could cause the unit to lock up.
b) Disconnect timer set too highGo to Network > advanced screen and set the disconnect timer to 7-10 seconds. A high 20-30 second disconnect timer means that each Voice2 unit server or client must wait for the timeout value to count down before attempting a reconnect
SolutionAfter checking the settings on the voice units it was found
That on the client unit, 2 channels had the jitter buffer min set to 0, perhaps making it 20 would helpA simple way to check the min / max jitter settings is to ping the voice unit from your PC and see the resultant ping values add an over head of 20-40ms to both the min and max values shown on your PC..
Other possible solutions a) Trace level set too high: Go to Config> admin> log screen and ensure the trace level is set to 1 or 2 .... the higher the trace level (max level is 4) the more higher the CPU utilisation which could cause the unit to lock up.
b) Disconnect timer set too highGo to Network > advanced screen and set the disconnect timer to 7-10 seconds. A high 20-30 second disconnect timer means that each Voice2 unit server or client must wait for the timeout value to count down before attempting a reconnect
, multiple selections available,
Related content
IP-Voice: VoICE unit locked up requiring power cycle to recover
IP-Voice: VoICE unit locked up requiring power cycle to recover
More like this
IP Voice: VoICE units disconnect after about 15 min and they reconnect automatically at times
IP Voice: VoICE units disconnect after about 15 min and they reconnect automatically at times
More like this
IP-Voice: Audio dropouts when using Voice2 units
IP-Voice: Audio dropouts when using Voice2 units
More like this
Voice2: Voice unit keeps dropping the line and locking up
Voice2: Voice unit keeps dropping the line and locking up
More like this
IP-Voice: What are some solutions for combatting VoICE issues?
IP-Voice: What are some solutions for combatting VoICE issues?
More like this
IP: Voice 2 upgrade from version 2.0.5 to version 2.1.0 fixes
IP: Voice 2 upgrade from version 2.0.5 to version 2.1.0 fixes
More like this
CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT
This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..
The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.