Matrix: Can I upgrade an M+3 panel to Eclipse by using the Eclipse firmware updater in ECS?

Matrix: Can I upgrade an M+3 panel to Eclipse by using the Eclipse firmware updater in ECS?

Matrix +3 legacy panels (ICS-52, 62, 92, 102, 2003, 1008 and 1016) CANNOT be converted to Eclipse format by connecting them to an existing Eclipse frame port and using the Eclipse firmware updater program.  The two formats are not compatible and therefore the M+3 panel will not handshake to the Eclipse frame port. 
In order to "convert" a M+3 panel to Eclipse format the M+3 panel will need to have the following done:
1.  Replace the existing M+3 EPEOM with an Eclipse formatted EPROM
or
2.  Use an existing Matrix +3 frame and a customized M+3 firmware updater (available by request from Clear-Com technical support) to convert the panel to Ecllipse format

Related content

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.