Wireless: How do I find the Application version of a CellCom splitter ?

Wireless: How do I find the Application version of a CellCom splitter ?

To determine the application version of a CellCom splitter it must be removed from service and the following procedure used to determine these parameters:
1.  Connect the splitter to a PC running Tera-Term software (this program can be found on the CellCom Toolkit CD) via a PD-4007 (beltpack registration) cable
2.  Set up Tera-Term to a available com port, set up the serial port parameters as follows:
     Baud Rate:  19200     Data:           8 bit     Parity:         None     Stop:           1 bit     Flow Cntl:    None
3.  Locally power up the splitter using the supplied PSU with 4-pin Din connector.  This will toggle a message to the Tera-Term terminal program, see below for an example of the actual screen:

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.