Matrix: How to configure ICS-22 panels for use with ECS / Eclipse systems

Matrix: How to configure ICS-22 panels for use with ECS / Eclipse systems

Although it may seem strange ICS-22 wall mount panels are configured as ICS-1008 Product Code in ECS, this is not a problem of the system nor does not mean that ECS is not recognizing the panel if you use 'hardware discovery', but that is the way the system works.
To configure the ICS-22 panels in ECS:
1. The port is declared as ICS-1008 in Matrix hardware.
2. In the panel programming key configuration use the first two buttons on the left, configure the top button as listens and the lower as talks.
NOTE:  All the other buttons on the ICS-1008 Panel mimic are not programmable nor do they work

3. It is necessary to configure the listens (green keys) on the top row buttons and talks (red keys) on the bottom row of buttons, reversing the talk and listen keys will cause the panel to not properly function when connected to the programmed port.
4. Send the changes to the frame to complete the operation. 
More information can be found in the manual of ECS: 810583ZA-Eclipse ECS User Guide.pdf; p. 5-14
For a Spanish translation of this solution please refer to solution 00002437. 

Related content

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.