Matrix: How to reset E-32 matix to factory default IP address
From Eclipse 4.2 release onwards a factory default IP address (172.16.2.100) is set up in the matrix firmware which will always be available via an IP reset. This ensures that once the matrix firmware is loaded it will always be possible to access the matrix via Ethernet even if the current IP address is not known.
To carry out an IP reset it is necessary to remove the cover of the Eclipse-32 in order to access the three reset switches positioned at the front left of the main circuit board (viewed from the front of the unit) shown in Figure 2-2.
To carry out an IP reset press and hold the rightmost two switches (nearest the side of the case) simultaneously and then press and release the ‘RESET’ button at the front of the unit, then release the internal switches. Power cycle the unit. The unit will then be reset to the factory default IP address.The unit cover should be replace immediately the operation is completed.
Warning: As the unit must be powered when resetting the IP address this operation should only be carried out by qualified service personnel.
CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT
This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..
The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.